Siemens S7-200 PLC data length and value range - Database & Sql Blog Articles

Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM
SMD aluminum electrolytic capacitor
The probe capacitor polarity needle has a head diameter of 5.8. The total length of the 7-pin and 12-pin needles is 5.

Different data lengths can be used when addressing Siemens S7-200 plc. Different data lengths indicate different ranges of values. The S7-200 instructions also require different data lengths. The data types stored in the storage unit of the S7-200 series are Boolean (BOOL), integer (INT), real type and string type. The data length and value range are listed in Table 6. Table 1 data length and value range

Data type data length byte (8-bit value) word (16-bit value) double word (32-bit value) unsigned integer 0 to 255
0~FF0~65535
0~FFFF0~4294967295
0 to FFFF FFFF signed integer -128 to +127
80~7F-32768~+32767
8000~7FFF-217483648~+2147483647
8000 0000~7FFF FFFF real IEEE32-bit floating point number+1.175495E-38~+3.402823E+
38 (positive number)
-1.175495E-38~-3.402823E+38
(negative number) ● The real number of the real number (floating point number) is represented by a 32-bit single-precision number in the format described in the ANSI/IEEE 754-1985 standard. The real number is accessed in accordance with the length of the double word. For the S7-200, the floating point number is accurate to the sixth decimal place. Therefore, when using a floating-point constant, you can specify up to the sixth digit after the decimal point.
● The precision of real operations involves very large and very small numbers in the calculation, which may result in inaccurate calculation results.
● The format string of a string refers to a series of characters, each of which is stored in bytes. The first byte of the string defines the length of the string, which is the number of characters. A string can be from 0 to 254 characters long, plus a length byte. The maximum length of a string is 255 bytes. The maximum length of a string constant is 126 bytes.
● Boolean data (0 or 1).
● The S7-200 CPU does not support data type detection. For example, you can use the value in VW100 as a signed integer in the add instruction, and you can also treat the data in VW100 as an unsigned binary number in the XOR instruction.
● The S7-200 provides various conversion commands, which allows users to easily change the data format and expression.

Cable Terminals

Our company specializes in the production and sales of all kinds of terminals, copper terminals, nose wire ears, cold pressed terminals, copper joints, but also according to customer requirements for customization and production, our raw materials are produced and sold by ourselves, we have their own raw materials processing plant, high purity T2 copper, quality and quantity, come to me to order it!

Cable Terminals

Taixing Longyi Terminals Co.,Ltd. , https://www.longyicopperlugs.com

Posted on