15KV SAC Cable

 

1. Application of Service Drop Cable: 
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 

2. Type of Service Drop Cable: 
Service Drop Cable(ABC CABLE) covers mainly three types: 
Duplex Service Drop 

Triplex Service Drop 
Quadruplex service drop


The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 

3. Detaild Introduction of Service Drop Cable 

3.1 Duplex Service Drop 

Applications 
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.2 Triplex Service Drop 

Applications 
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.3 Quadruplex Service Drop 

Applications 
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. 

Construction 
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated and Sheath with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.


Sac Cable 3X95mm2 35kv XLPE Power Cable
Sac Cable 3X95mm2 35kv XLPE Power Cable
Sac Cable 3X95mm2 35kv XLPE Power Cable

Cross Flow Cooling Fan

Cross flow fans are mainly used for air conditioners, air curtain equipment, dryers, dry-type transformers, household appliances and equipment on grain combine harvesters

Service conditions of transformer cooling fan:
1. The ambient temperature shall be+75 ℃ ≥ - 40 ℃.
2. The industrial gas passing through the cooling fan is not allowed to have strong acid, strong alkali and various solutions.
3.Sand and dust and other sundries are not allowed to fall into the fan, so as to avoid fan burning and fan blade breakage.

Working principle
When GF series cooling fan is used for dry-type transformer, the fan is placed on both sides of the coil, and the cold air is directly blown into the high and low pressure cooling air passages of the dry-type transformer coil, which has obvious heat dissipation effect, ensuring the normal operation of the dry-type transformer and prolonging its service life. Fan start stop, transformer overtemperature alarm, overtemperature trip and other functions are provided by the temperature control device.

Maintenance and use
1. Before the fan is used, the insulation resistance shall be tested to be greater than 2 megohms. When the fan is hot or humid, the insulation resistance shall not be less than 0.5 megohms.
2. Before starting the fan, please check whether the appearance is intact, whether the connection is reliable, and whether the wind wheel rotates flexibly without blocking.
3. Clean the dust in the fan regularly to prevent affecting the air volume.

Cross Flow Cooling Fan,Copper Cross Flow Fan,Transformer Cooling Fan,Top Blowing Series Cooling Fan

Henan New Electric Power Co.,Ltd. , https://www.newelectricpower.com

Posted on