Humidification tester <Operation and test method>-华强电子网

Kaixin micro test
Test - lowercase jpg
Test probe PH-5H

one,

purpose

When the soil is humidified, the soil disintegrates in the water.

The instrument is suitable for determining the disintegration speed of a structured clay soil in water, and is one of the criteria for selecting soil materials by wet dam construction.

two,

Reference Standard:

SL237-003 (water content test)

SL237-004 (density test)

three,

Operation and test:

1. Take the undisturbed soil as needed or prepare the soil sample in the desired state with the disturbed soil, and cut it into a cube sample with a side length of 5 cm with a soil cutter.

2. Determine the moisture content and density of the sample according to the regulations SL237-003 and SL237-004.

3. Place the sample in the center of the stencil. The stencil is hung under the pontoon. Then hold the front end of the pontoon and quickly immerse the sample into the water cylinder to start the stopwatch.

4. Immediately start the measurement is the instantaneous stable reading and starting time of the scale at the surface of the float.

5. After the test starts, press 1, 3, 10, 60min, 2, 3, 4... to measure the scale reading at the water surface of the float, and describe the disintegration of the sample at each reading, according to the speed of disintegration of the sample. The time interval for reading can be shortened or increased as appropriate.

Fourth, the humidification test record

Project Code: Soil Sample Number: Instrument Number: Soil Sample Description:

Tester: Calculater: Checker: Test water:

Density (g/mm2) Moisture content (%)

Observation time

after

time

float

reading

float

Poor reading

Disintegration amount

(%)

Disintegration

years

Dbmin

H.min

R

1

R

1

-R2

λ=

(R

1

-R

2

)/(100-R

λ

)100

V. Results

1,

The test ends when the sample completely falls through the grid. If the sample does not disintegrate for a long time, record the sample in water.

λ=(R

1

-R

2

)/(100-R

λ

)100

λ: the amount of disintegration of the test piece at time S, %

R1: Scale reading at the surface of the float at time S.

R2: The stable reading of the scale at the surface of the float at the beginning of the test piece.

Note: There is a water level line on the water tank. When the water level is not applied, the water level can be added to the line, so as to avoid the water overflowing after the test piece and the float tube are placed! !

Car Charger

Product Name: Car Charger

Place of Origin: Guangdong, China (Mainland)

Brand Name: OEM

Output Type: DC

Connection: Other

Rated Voltage: 12V-24V

Working Temp: 0-55℃

Weight: 36g

Materials: PC+ABS

Color: White Black

Warranty: 1 year

Suitable for:Most digital devices


SMART PROTECTION & ATTRACTIVE DESIGN ------ Intelligent circuit design protects against short circuiting,over-heating,over-current,and over-charging. Charging stops when battery is full. Car charger with blue LED indicator,which makes it convenient to find exactly where the connection should go; And the light is soft enough not to distract at night.