The problem of humming sound when karaoke reverberator sings

Karaoke reverb is one of the necessary audio equipment for KTV rooms. So what does the reverberer do? The main function of the reverberator is to increase the artificial reflection sound, and the artificial reflection sound can cover the defects of the singer's singing skills, and perform reverberation, delay, and excitation on the original human voice. Today we are talking about the problem of vocalization when the karaoke reverberator sings.

Singing in the KTV room, sometimes the karaoke reverb is accompanied by a loud vocal. This phenomenon is caused by the short circuit between the microphone to the amplifying circuit board in the KTV room and the filter capacitor in the microphone amplifier circuit. So how should we solve it?

First, the KTV room maintenance staff checks if the ground wire in the microphone is good. The specific method of operation is to open the microphone handle and check whether the shielded ground wire and the metal part of its switch housing are well connected to the mesh in the microphone cable. When it is found that there is no connection and one end is open, it can be soldered with a soldering iron. Secondly, it is necessary for the KTV room equipment maintenance personnel to open the cover of the karaoke reverberator, check whether the grounding wire between the microphone input socket and the square circuit board is in good contact, and also need to look at the microphone volume potentiometer casing and the amplifying circuit. The ground wire contact between the boards is good. The inspection of these two parties is also very important. If the connection is not good, then the same method is used to solder them.

If no problem is found in the above two steps, then the filter electrolytic capacitor in the microphone amplifier circuit can be highlighted. Normally, if the circuit is open or the capacity is reduced, the humming sound will be generated during the accompaniment, and it can be replaced by the same model or a slightly larger capacity.

In addition, the karaoke reverb microphone input socket and the amplifier circuit board are connected by ordinary wires, and the connecting wires are long, so it is easy to sense the hum, and the audio cable with the shield layer is used to exchange it, so that Reduce the humming noise during accompaniment.

Today, in the audio technology knowledge, we simply understand the karaoke reverberation accompaniment when the vocal problem solving method KTV room equipment maintenance personnel must be self-study to understand, master the knowledge to be found in this area We will know more about how to solve it.

Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic