The test liquid is prepared by dissolving the reagent grade in distilled water (or water having a total dissolved solid content of less than 200 ppm) and formulating the test solution to a concentration of 5 ± 1%. After the test solution is sprayed at 35 ° C, the pH of the collected solution should be 6.5 to 7.3. And before the spraying, the test liquid cannot contain the floating matter.
1. Chlorinated sodium cannot contain impure impurities of copper, and the content of solids is less than 0.1%. Since the impurities may contain corrosion inhibitors, the total impurity content must be less than 0.3%.
2. The specific gravity of the test solution should be 1.0258-1.0402 between 33 and 35 °C, and the specific gravity at 25 °C is 1.0292-1.0443. The concentration of the test solution can also be determined by silver nitrate droplet method or other methods.
3. The test solution shall be adjusted to pH value with a reagent-grade hydrochloric acid or a dilute solution of sodium hydroxide, and measured by a pH meter or other reliable method. The solubility of water in the water containing the test solution contains carbon dioxide and carbon dioxide in the water. The pH of the solution, so the pH should be carefully controlled, and the pH can be adjusted by any of the following methods:
1. Prepare the test solution at room temperature and spray at 35 ° C. As the temperature increases, some of the carbon dioxide will escape from the solution and raise the pH. Therefore, when the test solution is prepared at room temperature, the pH should be adjusted within 6.5 to make the pH of the collected solution between 6.5 and 7.3.
2. Before the pH adjustment, the test solution is first boiled and then cooled to 35 ° C, or maintained at 35 ° C for 48 hours. When the pH thus adjusted is sprayed at 35 ° C, there will be no significant change.
3. The water is first heated to above 35 ° C to remove dissolved carbon dioxide, and then the test solution is adjusted and the pH is adjusted. Thus, when the spray is sprayed at 35 ° C, the adjusted pH value does not change too much.
4. In order to avoid the nozzle from clogging, the test solution should be filtered or carefully tilted into the salt water tank, or filtered at the front end of the spray suction pipe. Kunshan Zhenhong Salt Spray Corrosion Test Chamber is equipped with a glass sieve filter at the front end of the spray suction pipe.
Mini Circuit breakers, also named as the air switch which have a short for arc extinguishing device. It is a switch role, and also is a automatic protection of low-voltage electrical distribution. Its role is equivalent to the combination of switch. Fuse. Thermal Relay and other electrical components. It mainly used for short circuit and overload protection. Generally, According to the poles, mini Circuit breaker can be divided into 1P , 1P+N , 2P, 3P and 4P.